Split Chamber Type (Outdoor) DC Charger

Split chamber type (outdoor) DC charger is used for electric vehicle charging power supply of distributed charging network. It can deploy charging network rapidly and effectively, providing high-power charging service for electric vehicles. The split chamber type (outdoor) DC charger should be used with charging terminal. It is applicable to expressway, urban public parking lot, bus station, enterprises’ parking lot, etc.

Split Chamber Type (Outdoor) DC Charger

Intelligent monitoring: The intelligent controller of charging pile has the functions of measuring, controlling and protecting charging pile, such as operating status monitoring, fault condition monitoring and linkage control of charging process.

Intelligent metering: AC output is equipped with AC intelligent electric meter for implementing AC charging metering, which has perfect communication function and it can upload information respectively to charging intelligent controller and network operating platform via RS485.

Scan code charging: Scan QR code with charging pile mobile phone client to charge.

Protection function: It has complete protection functions, such as input and output overvoltage and undervoltage protection, short circuit protection, overcurrent protection, leakage protection, grounding detection and overtemperature protection.

High compatibility: Charging device is compatible with national standard models of vehicle on the market.

Adjustable power: Charging power is adjustable meeting the requirement of different vehicles in family or work place.

IP rating: IP54.

MODEL

EVXG-1900

EVXG-3100

EVXG-4300

INPUT

Input voltage

260 V ~ 456 V (three phase five wire:L1,L2,L3,N,PE)

Input current

≤ 535 A

≤ 1070A

≤ 1605A

AC Input frequency

45 Hz ~ 65 Hz

Efficiency

≥ 95%

Power factor

≥ 0.99

Input THD

≤ 5%

OUTPUT

Output power

2 × 150 KW

4 × 150 KW

6 × 150 KW

Number of charger

2

4

6

Soft start time

3 s ~ 8 s

Output constant-current range

10% ~ 100%

Voltage regulation accuracy

≤ ± 0.2%

Current regulation accuracy

≤ ± 0.5%

Ripple coefficient (peak value)

≤ 1%

Current-sharing unbalanced degree

≤ ± 3% (50% ~ 100% rated load)

Noise

< 55 dB

PROTECTIONS

Output short-circuit protection

Retraction current ≤ 40% Io; auto-restorable

Output overvoltage protection 

No output after protection;
non-restorable (require manual restoring)

Input over/under voltage protection

No output after protection; auto-restorable

Phase-lack protection

No output after protection; auto-restorable

Overtemperature protection

No output after protection; auto-restorable

CHARGING CONFIGURATION AND STANDARD

Charging plug number

4

8

12

Charging cable length

5 m

Communication protocol standard

GB/T 27930-2015

Charger standard

GB/T 18487.1-2015, GB/T 20234.1-2015, GB/T 20234.3-2015, NB/T 33001-2010, NB/T 33008.1-2013

OTHERS

Operating  temperature

-20℃ ~ + 50℃

Storage temperature

-40℃ ~ + 80℃

Relative humidity

≤ 95%

Atmospheric pressure

70 kPa ~ 106 kPa

IP rating

IP 54

Dimensions (H × W × D) (mm)

2400× 1900 × 1100

2400 × 3100 × 1100

2400 × 4300 × 1100

Weight (kg)

≤ 900

≤ 1650

≤ 2350