EA900II RT 6~ 10KVA

EA900II RT 6KVA~10KVA online UPS is the high density version of on-line double-conversion UPS with input power factor correction (PFC), output power factor 0.9 offering high levels of reliability and protection for IT systems, telecommunications equipment and mission critical systems. The UPS is rack and tower convertible, and takes up only 2-3U in height. For critical business continuity applications requiring long runtimes, EA900IIRT UPS (long time model)can be installed with battery extension packs.

EA900II RT 6~ 10KVA

Rack / Tower design

High frequency and true double-conversion

DSP digital control technology

Input power factor correction (PFC)

Wide input voltage range (110 V ~ 300 V)

Output power factor 0.9

Cold start

Auto sensing frequency

ECO mode operation for energy saving

Selectable output voltage via LCD

50 Hz / 60 Hz frequency conversion mode

Selectable battery low voltage via LCD

Power-on self test

Advanced battery management (ABM)

Short circuit and overload protection

Automatic charging in OFF mode

Fan speed auto control when temperature varies

Standard RS232 communication port and RJ45 protection

Optional USB / SNMP communication port

Optional emergency power off (EPO)

Optional extension battery bank

Optional N+X redundancy parallel

MODEL

EA906IIRT

EA9010IIRT

Capacity

6 KVA / 5400 W

10 KVA / 9000 W

INPUT

Rated voltage

208 V / 220 V / 230 V / 240 Vac

Voltage range

Half load (115 ~ 295) ± 5 Vac,
full load (160 ~ 295) ± 5 Vac

Frequency

40 ~ 70 Hz ± 0.5 (auto-sense)

Power factor

≥ 0.99

Bypass voltage range

160 V ~ rated output voltage + 32 V

OUTPUT

Voltage

208 V / 220 V / 230 V / 240 Vac (settable via LCD)

Voltage regulation

± 1%

Frequency

Synchronized with utility in mains mode; 50 / 60 Hz ± 0.2 Hz in battery mode

Waveform

Sinusoidal

Crest factor

3:1

Harmonic distortion

≤ 2% (linear load); ≤ 5% (non-linear load)

Transfer time

Mains mode to battery mode: 0 ms
Inverter mode to bypass mode: 0 ms

Overload

105% ~ 125% for 3 mins, 125% ~ 150% for 30 s, >150% for 0.5 s

EFFICIENCY

Mains mode

≥ 92%

Battery mode

≥ 91%

ECO mode

≥ 98%

BATTERIES

DC voltage

192 V

Inbuilt battery of standard model

16×7 Ah

16×9 Ah

Charging current

Standard model

1 A

Long time model

1 A / 3 A / 5 A / 8 A

Recharge time

8 h

ALARMS

Utility failure

4 s per beep

Low battery

1 s per beep

Overload

1 s twice beep

UPS fault

Long beep

COMMUNICATIONS

RS232 (standard), USB (optional)

Supports Windows® 98 / 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10

SNMP (optional)

Power management from SNMP manager and web browser

OTHERS

Humidity

20 ~ 90% RH @ 0 ~ 40℃ (non-condensing)

Noise level

≤ 55dB (1m)

Long time model

Dimensions (W×D×H) (mm)

440×580×132 (UPS)

Packaged dimensions (W×D×H) (mm)

530×703×227 (UPS)

Net / Gross weight (kg)

16.4 / 20.7

17.1 / 21.4

Standard model

Dimensions (W×D×H) (mm)

440×580×132 (UPS), 440×580×132 (BAT)

Packaged dimensions (W×D×H) (mm)

530×703×227(UPS), 530×703×227 (BAT)

Net / Gross weight (kg)

16.4 / 20.7 (UPS)
43.6 / 47.1 (BAT)

17.1 / 21.4 (UPS)
49.6 / 53.1 (BAT)

Download